Whatsapp:+86 156 6609 5066
AA320N  Atomic absorption spectrophotometer
1%
OFF

AA320N Atomic absorption spectrophotometer

0 customer reviews {{parseInt(detail_data.left_num) ? 'In Stock.' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}} SKU.161199
  • {{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }}

    {{parseInt(detail_data.left_num) ? detail_data.left_num +' In Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}

$   7,840
$ 7,900 save $ 60
{{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }} {{detail_data.displayed_price.ex_sell_type}}
{{ item.num }} pieces
$ {{ item.price }}
{{item.name}}* {{item.values[0].value}}
{{sku.value}}
Quantity:
{{detail_data.displayed_price.unit_type_name}}(s)
( Min. Order {{detail_data.prodInfo.minimum_ordered_quantity}} )
Shipping:
{{ detail_data.displayed_price.unit_prefix }} {{now_chooseship.price}}
Free Shipping
Can't deliver
To Be Negotiated
to United States Change
Estimated delivery time : {{now_chooseship?now_chooseship.datemin:''}}-{{now_chooseship?now_chooseship.datemax:''}} working days. See details
Total Price:
$ 7,840 $ 7,900 save $ 60
Shipping calculated at checkout.
Weight:
{{Number(packInfo.weight).toFixed(2)}} KG
Package:
{{packInfo.length}}cm*{{packInfo.width}}cm*{{packInfo.height}}cm
  • Description
  • Characteristics

    1,Build-in computer data processing and LCD display,stable and reliable with the functions of integral holding,peak height and area,auto zero adjusting ,deuterium lamp background correction,multi-linear and nonlinear curves fitting,various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
    2,Stability,double-beam system can automatically compensate the light source drift and wavelengthdrift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability.
    3,Quickly,The cathode lamp needs not be pre-heated for long time and sample can be analyzed immediately. It is the preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.4,High precision of measurement,Gas path system is equipped with precision pressure stabilizing and current stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration.
    5,High energy optical path,A total reflection system is adopted to eliminate color difference in full range. By means of chemical conversion, a round light spot of the light source becomes a long light spot,which enters into the slit.Therefore the light flux of double beam is enhanced.
    6,Long-life and anti-corrosive atomization system,The burner is made of new type titanium alloys, anti-corrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
    7,Multi-functional analysis mode, for methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
    8,Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used to analyze
    air-acetylene flame.
    9,Complete set of accessories, to be supplied with the instrument and ready for use after they are purchased.

    Standard Accessories
    Oil-free air compressor
    Glass Atomizer
    Cu Hollow cathode lamp
    Atomizer unit
    Burner unit
    Dust cover
    Water-separating gas filter
    Titanium burner---10cm

    Optional Accessories
    Model GA3202 HGA graphite furnace system
    Hydride generator
    Hollow cathode lamp
    Graphite tubes Software
    Recirculating cooling water system
    Technical Specification

    Model GA3202 HGA graphite furnance system
    1,Heating steps, 9 steps
    2,Temperature range (nominal Temperature),20℃ - 3000℃
    3,Slope heating time,0-999s
    4,Heating holding time,1s-999s (the sum of both time should be less than 999 seconds)
    5,Inert gas needed,argon, pressure of entry larger than 0.3Mpa
    6,Cooling water, tap water or cycling water, flow rate no less than 2L/min
    7,Output: LCD
    8,Gas pressure alarm, furnace overheated alarm
    9,Interface with Atomic absorptionspectrophotometer, autosampler and RS232
    10,High-power temperature heating function (1000℃ - 2700℃ )
    11,Test sample together with atom absorption equipment. Cd≤1 x10-12g;Cu≤1x10-10g
    12,Working Conditions,
    Power source,220V±22V, 50Hz± 1Hz, 3A/ 220V±22V, 50Hz±1 Hz,30A
    Power,5.1kW for 220V on about 2700℃
    Ambient temperature,+10℃- +30℃
    Relative humidity,less than 85% Instrument rating power, 7.2kW
  • Specification
  • Model No
    AA320N
    AA321N
    AA322N
    AA323N
    Wavelength Range
    190-900nm
    190-901nm
    190-902nm
    190-903nm
    Wavelength Accuracy
    ≤±0.5nm
    ≤±0.6nm
    ≤±0.7nm
    ≤±0.8nm
    Wavelength Repeatability
    ≤0.3nm (single direction)
    ≤0.4nm (single direction)
    ≤0.5nm (single direction)
    ≤0.6nm (single direction)
    Spectrum Bandwidth
    0.2nm/0.4nm/0.7nm/1.4nm/2.4nm/5.0nm
    0.2nm/0.4nm/0.7nm/1.4nm/2.4nm/5.1nm
    0.2nm/0.4nm/0.7nm/1.4nm/2.4nm/5.2nm
    0.2nm/0.4nm/0.7nm/1.4nm/2.4nm/5.3nm
    Resolution
    <40%
    <41%
    <42%
    <43%
    Baseline stability
    ±0.004Abs/30min
    ±0.004Abs/31min
    ±0.004Abs/32min
    ±0.004Abs/33min
    Characteristic concentration of copper
    ≤0.04μg/ml/1%
    ≤0.04μg/ml/2%
    ≤0.04μg/ml/3%
    ≤0.04μg/ml/4%
    Detection limit of copper
    ≤0.008μg/ml
    ≤0.009μg/ml
    ≤0.010μg/ml
    ≤0.011μg/ml
    Background calibration ability
    Greater than 30 times
    Greater than 31 times
    Greater than 32 times
    Greater than 33 times
    Interface
    RS232
    RS233
    RS234
    RS235
    Printer
    optional
    optional
    optional
    optional
    Power Supply
    AC 110-240V, 120W
    AC 110-240V, 121W
    AC 110-240V, 122W
    AC 110-240V, 123W
    Gross Weight
    160Kg, 65Kg
    160Kg, 66Kg
    160Kg, 67Kg
    160Kg, 68Kg
    Package Dimensions
    1200x770x7300mm (main instrument)
    1200x770x7301mm (main instrument)
    1200x770x7302mm (main instrument)
    1200x770x7303mm (main instrument)
  • Customer Reviews
  • Customer Reviews
    • Write a Review
      Average Rating:
      {{stardata.star}}
      based on {{comment.count}} reviews
    • {{comment.star5}}%
      {{comment.star4}}%
      {{comment.star3}}%
      {{comment.star2}}%
      {{comment.star1}}%
    No data
    AA320N  Atomic absorption spectrophotometer
    {{comments.user.name}}
    Verified Purchase
    {{comments.rating}}.0
    {{comments.date_added}}
    {{comments.topic}}
    {{comments.text}}
    Showing {{comments.replies.length}} comment

    {{reply_items.text}}By {{reply_items.author}}

  • Questions & Answers
  • Questions & Answers
    Ask a Question
    No data
    Your Browsing History
    {{item.displayed_price.rate_of_discount}} %
    OFF

    {{item.detail.name}}

    {{item.displayed_price.unit_prefix}} {{item.displayed_price.min}} {{item.displayed_price.unit_prefix}}  {{item.displayed_price.original_min}}

    Currency: USD
    USD - US Dollar
    EUR - Euro
    GBP - British Pound
    CAD - Canada Dollars
    AUD - Australia Dollars
    JPY - Japan Yen
    SEK - Sweden Kronor
    NOK - Norway Kroner
    IDR - Indonesia Rupiahs
    BRL - Brazil Reais
    RUB - Russia Rubles
    THB - Thailand Baht
    AED - Arab Emir. Dirham
    Need Help?
    Chat live with us
    Request Quote
    Track Order
    Want to check the status of your order? You can put in your order number and click track order to find the tracking information or login your account to check the detail information.
    order number
    • order number
    • tracking number