Whatsapp:+86 156 6609 5066
AA4530F Atomic absorption spectrophotometer
2%
OFF

AA4530F Atomic absorption spectrophotometer

0 customer reviews {{parseInt(detail_data.left_num) ? 'In Stock.' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}} SKU.161197
  • {{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }}

    {{parseInt(detail_data.left_num) ? detail_data.left_num +' In Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}

$   13,512
$ 13,800 save $ 288
{{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }} {{detail_data.displayed_price.ex_sell_type}}
{{ item.num }} pieces
$ {{ item.price }}
{{item.name}}* {{item.values[0].value}}
{{sku.value}}
Quantity:
{{detail_data.displayed_price.unit_type_name}}(s)
( Min. Order {{detail_data.prodInfo.minimum_ordered_quantity}} )
Shipping:
{{ detail_data.displayed_price.unit_prefix }} {{now_chooseship.price}}
Free Shipping
Can't deliver
To Be Negotiated
to United States Change
Estimated delivery time : {{now_chooseship?now_chooseship.datemin:''}}-{{now_chooseship?now_chooseship.datemax:''}} working days. See details
Total Price:
$ 13,512 $ 13,800 save $ 288
Shipping calculated at checkout.
Weight:
{{Number(packInfo.weight).toFixed(2)}} KG
Package:
{{packInfo.length}}cm*{{packInfo.width}}cm*{{packInfo.height}}cm
  • Description
  • Characteristics

    1,Completely controlled by PC
    2,Integrated floated optical platform design can obviously improve the optical system shock resistance and keep stable though use the optical signal for a long term
    3, Eight light standscan be changed automatically and preheat the eight lights meantime as well as optimize the working
    conditionof the hollow cathode lamp.
    4, Position adjusting, the best height of the flame burner and can automatically set the front and rear positions.
    5,Fully automated wavelength scanning and peak searching
    6,Complete safety chains protection equipment: the function of warning and automatic safety protection towards the wrong burner, leakage of the gas, under voltage of air and the abnormal flameout.
    7,Deuterium lamp and self-absorption background regulation.
    8,Data processing: super strong database, possesses more than 500 data self-storage and cut-off storage function, can store the analyzed result with the form of EXCEL and the testing method and the result can be randomly called.
    9,Measuring method: flame absorption method and emission method.
    10,Result printing: parameter printing, data result printing and diagram printing

    Complete Automatic Controlling System
    With the help of the software, the following can be easily achieved
    1,Selection of the element lamp
    2,Up-down-front-rearadjustment of the lifter
    3,Adjustment of the optical energy
    4,Selection of the slit
    5,Determinationof wavelength scanning and peak searching
    6,Selection of the atomizer
    7,Setting of the background deduction method
    8,Controlling of the gas flow
    9,Automatic flaming and flaming out
    10,Setting of the graphite furnace testing method

    Advanced Graphite Furnace Temperature Controlling Technology
    * The bringing in of PIO technology can effectively overcome the influence on the temperature rising process caused by the voltage fluctuation and the resistance change to make more accurate controlling process. The combination of the 3ms/time fast sampling technique can make more accurate and reliable testing data.
    * The fast heating capacity can improve the flexibility of the elements further
    * Use the ordinary power source of 220V without need of dynamic power of 380V
    * The maximum procedure heating capacity setting of 20 levels can make a more convenient and easier test of different samples
    * Three grades adjustable gas flow can accustom to more application needs
    * Can timely alarm when the gas and water is stopped and insufficient gas and water, can avoid the equipment damage and measuring error

    Safe, reliable and convenient flame system
    * EPC can control the flow of Acetylene (C2H2)more accurately and it is a kind of system which also can be operated easily.
    * Efficient atomization system enables a higher sensitivity.
    * The whole operation system has a high security as the fire safety system can alarm whenever the electrici­ ty is cut off,
    abnormal flame occurs, a lack of pressure happens or the burner does not match well. And it will automatically turn off the
    gas, prohibit tempering. Thus it keeps the operation people and equipment from harm and damage.

    Multi-Functional Software Workstation
    * A workstation that is supported WINDOWS 7
    * The rich menu brings great convenience to the use of customer
    * Convenient conversion between different menus makes the operation more easily
    * Various analytical correction methods provide the users more choices
    * Basic default parameter settings enable even the beginners can do the normal operation
    * Flexible storage , editing and printing methods give the user largest support
  • Specification
  • Model No
    AA4530F
    Wavelength Range
    190-900nm
    Spectrum Bandwidth
    0.1/0.2/0.4/1.0/2.0nm
    Wavelength Accuracy
    ±0.15nm
    Wavelength Receptivity
    ≤0.04nm
    Baseline stability
    ±0.002Abs/30min(Cu)
    Characteristic viscosity
    0.02μg/ml/1% (Cu)
    Checking limit
    0.004μg/ml (Cu)
    Preciseness
    0.50%
    Grating
    1800 lines/mm
    Inflamer
    All-metal titanium burner
    Atomizer
    Effective glass atomizer
    Lamp stand
    8
    D2 background correction ability
    self absorption background deduction method, when the background is 1A, the background ability should be deducted no less than 50 times
    Power Supply
    AC 110-240V, 120W
    Size and weight
    700x550x450mm/75Kg
    Flame system
    Acetylene air burner
    100mm
    Ignition dynamic baseline drift
    ≤0.006Abs/30 min
    (Cu) Characteristic viscosity
    0.025μg/ml/1%
    Related standard accuracy deviation
    ≤0.5%(Cu, absorbance>0.8A)(detection limit Cu ≤0.008μg/ml)
    Safety system
    when pressure is insufficent, the system automatically cut off the gas and power off, flame out and unconformity of the burner
    Graphite Furnace
    Temperature upper limit
    3000℃
    Largest temperature rise speed
    ≥2000℃/second
    Characteristic quantity
    Cd≤0.5×10-12g Cu≤0.5×10-11g
    Accuracy
    Cu≤3% Cd≤3%
    Safety system
    Over current protection /Low air pressure alarm / protection
    Low cooling water flow alarm/protection
    Size and weight
    550mm×450mm×300mm 65Kg
  • Customer Reviews
  • Customer Reviews
    • Write a Review
      Average Rating:
      {{stardata.star}}
      based on {{comment.count}} reviews
    • {{comment.star5}}%
      {{comment.star4}}%
      {{comment.star3}}%
      {{comment.star2}}%
      {{comment.star1}}%
    No data
    AA4530F Atomic absorption spectrophotometer
    {{comments.user.name}}
    Verified Purchase
    {{comments.rating}}.0
    {{comments.date_added}}
    {{comments.topic}}
    {{comments.text}}
    Showing {{comments.replies.length}} comment

    {{reply_items.text}}By {{reply_items.author}}

  • Questions & Answers
  • Questions & Answers
    Ask a Question
    No data
    Your Browsing History
    {{item.displayed_price.rate_of_discount}} %
    OFF

    {{item.detail.name}}

    {{item.displayed_price.unit_prefix}} {{item.displayed_price.min}} {{item.displayed_price.unit_prefix}}  {{item.displayed_price.original_min}}

    Currency: USD
    USD - US Dollar
    EUR - Euro
    GBP - British Pound
    CAD - Canada Dollars
    AUD - Australia Dollars
    JPY - Japan Yen
    SEK - Sweden Kronor
    NOK - Norway Kroner
    IDR - Indonesia Rupiahs
    BRL - Brazil Reais
    RUB - Russia Rubles
    THB - Thailand Baht
    AED - Arab Emir. Dirham
    Need Help?
    Chat live with us
    Request Quote
    Track Order
    Want to check the status of your order? You can put in your order number and click track order to find the tracking information or login your account to check the detail information.
    order number
    • order number
    • tracking number