Whatsapp:+86 156 6609 5066

AA4530F Atomic Absorption Spectrophotometer for Laboratory Determination of Metal Elements

0 customer reviews {{parseInt(detail_data.left_num) ? 'In Stock.' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}} SKU.106195
  • {{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }}

    {{parseInt(detail_data.left_num) ? detail_data.left_num +' In Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}

$   10,000
{{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }} {{detail_data.displayed_price.ex_sell_type}}
{{ item.num }} pieces
$ {{ item.price }}
{{item.name}}* {{item.values[0].value}}
{{sku.value}}
Quantity:
{{detail_data.displayed_price.unit_type_name}}(s)
( Min. Order {{detail_data.prodInfo.minimum_ordered_quantity}} )
Shipping:
{{ detail_data.displayed_price.unit_prefix }} {{now_chooseship.price}}
Free Shipping
Can't deliver
To Be Negotiated
to United States Change
Estimated delivery time : {{now_chooseship?now_chooseship.datemin:''}}-{{now_chooseship?now_chooseship.datemax:''}} working days. See details
Total Price:
$ 10,000
Shipping calculated at checkout.
Weight:
{{Number(packInfo.weight).toFixed(2)}} KG
Package:
{{packInfo.length}}cm*{{packInfo.width}}cm*{{packInfo.height}}cm
  • Description
  • Graphite Furnace(Optional)

    Max. Temperature

    3000℃

    Max Heating Speed

    ≥2000℃/S

    Characteristic Quantity

    Cd≤0.5*10-12g Cu≤0.5*10-11g

    Accuracy

    Cu≤3% Cd≤3%

    Safety System

    Over current protection Low air pressure alarm / protection

    Low cooling water flow alarm/protection

    Power Supply

    220V, 50Hz

    Consumption

    7000W

    Packing Size(mm)

    550*450*300

    Gross Weight(kg)

    65

  • Specification
  • Technical Parameters

     

    Model

    AA4530F

    Wavelength Accuracy

    ±0.15nm

    Wavelength Receptivity

    ≤0.04nm

    Base Line Stability

    ≤0.002A/30min (Cu)

    Characteristic Concentration 

    0.02μg/ml/1% (Cu)

    Detection Limit

    0.004μg/ml (Cu)

    Measurement Repeatability

    ≤0.5%

    Grating

    1800 lines/mm

    Inflamer

    All-metal titanium burner

    Atomizer

    Efficient glass atomizer

    Lamp stand

    8

    D2 background Calibration

    When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

    Power Supply

    220V, 50/60Hz

    Packing Size(mm)

    850*700*750(Main instrument)

    950*620*1020(Accessories )

    Gross Weight(kg)

    105Kg  (Main instrument)

    100Kg   ( Accessories )

    Standard Accessories

    PC workstation

    HP inkjet printer 

    Oil free Air compressor

    Acetylene reducing valve

    Cu Hollow cathode lamp

    Air filter

    Optional Accessories

    Graphite Furnace

    Hollow cathode lamp(Ag, Au, Ba, Ca, Cd, Cr ,Fe, Hg ,K, Li, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

     

     

    Flame System

    Acetylene Air Burner

    100mm

    Ignition Dynamic Baseline Drift

    ≤0.006A/30min

    Characteristic Concentration

    ≤0.025μg/ml/1%(Cu)

    Related Standard Deviation of the Accuracy

     

    ≤0.5%(Cu, absorbance>0.8A) (detection limit Cu≤0.008μg/ml)

    Safety System

    Can automatically cut off the gas when the pressure is not enough, the power is off, flameout and unconformity of the burner.

     

     

    Graphite Furnace(Optional)

    Max. Temperature

    3000℃

    Max Heating Speed

    ≥2000℃/S

    Characteristic Quantity

    Cd≤0.5*10-12g  Cu≤0.5*10-11g

    Accuracy

    Cu≤3% Cd≤3%

    Safety System

    Over current protection Low air pressure alarm / protection

    Low cooling water flow alarm/protection

    Power Supply

    220V, 50Hz

    Consumption

    7000W

    Packing Size(mm)

    550*450*300

    Gross Weight(kg)

    65



  • Customer Reviews
  • Customer Reviews
    • Write a Review
      Average Rating:
      {{stardata.star}}
      based on {{comment.count}} reviews
    • {{comment.star5}}%
      {{comment.star4}}%
      {{comment.star3}}%
      {{comment.star2}}%
      {{comment.star1}}%
    No data
    AA4530F Atomic Absorption Spectrophotometer for Laboratory Determination of Metal Elements
    {{comments.user.name}}
    Verified Purchase
    {{comments.rating}}.0
    {{comments.date_added}}
    {{comments.topic}}
    {{comments.text}}
    Showing {{comments.replies.length}} comment

    {{reply_items.text}}By {{reply_items.author}}

  • Questions & Answers
  • Questions & Answers
    Ask a Question
    No data
    Your Browsing History
    {{item.displayed_price.rate_of_discount}} %
    OFF

    {{item.detail.name}}

    {{item.displayed_price.unit_prefix}} {{item.displayed_price.min}} {{item.displayed_price.unit_prefix}}  {{item.displayed_price.original_min}}

    Currency: USD
    USD - US Dollar
    EUR - Euro
    GBP - British Pound
    CAD - Canada Dollars
    AUD - Australia Dollars
    JPY - Japan Yen
    SEK - Sweden Kronor
    NOK - Norway Kroner
    IDR - Indonesia Rupiahs
    BRL - Brazil Reais
    RUB - Russia Rubles
    THB - Thailand Baht
    AED - Arab Emir. Dirham
    Need Help?
    Chat live with us
    Request Quote
    Track Order
    Want to check the status of your order? You can put in your order number and click track order to find the tracking information or login your account to check the detail information.
    order number
    • order number
    • tracking number