Whatsapp:+86 156 6609 5066

BIOSTELLAR BS-V1900PC Scanning UV/VIS Spectrophotometer

0 customer reviews {{parseInt(detail_data.left_num) ? 'In Stock.' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}} SKU.106155
  • {{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }}

    {{parseInt(detail_data.left_num) ? detail_data.left_num +' In Stock' :detail_data.zeroStockOrder==0?'Out of Stock':'Available'}}

$   1,500
{{ detail_data.displayed_price.unit_prefix }}  {{ detail_data.displayed_price.value }} {{detail_data.displayed_price.ex_sell_type}}
{{ item.num }} pieces
$ {{ item.price }}
{{item.name}}* {{item.values[0].value}}
{{sku.value}}
Quantity:
{{detail_data.displayed_price.unit_type_name}}(s)
( Min. Order {{detail_data.prodInfo.minimum_ordered_quantity}} )
Shipping:
{{ detail_data.displayed_price.unit_prefix }} {{now_chooseship.price}}
Free Shipping
Can't deliver
To Be Negotiated
to United States Change
Estimated delivery time : {{now_chooseship?now_chooseship.datemin:''}}-{{now_chooseship?now_chooseship.datemax:''}} working days. See details
Total Price:
$ 1,500
Shipping calculated at checkout.
Weight:
{{Number(packInfo.weight).toFixed(2)}} KG
Package:
{{packInfo.length}}cm*{{packInfo.width}}cm*{{packInfo.height}}cm
  • Description
  • Features

    *Adopted high-class grating with wholly hermetic light path design, to ensure the instrument has the super low stray light

    *Real-time monitoring the lifetime of Deuterium lamp and Tungsten lamp with advanced system

    *With GLP self-check function, check the wavelength accuracy and Photometry accuracy

    *Wavelength calibration, wavelength setting, change lamp source and dark current calibration automatically

    *With Si02 coating optical mirror, reducing the pollution from outside fully

    Basic Functions

    1, Photometry

    Test Abs., Transmittance and Energy by fixed wavelength

    2, Quantitative

    Linear fit and Linear fit through zero two modes

    a.Coefficient, Standard Sample input and Standard Sample read three modes to establish standard curve

    b. Establish A=K1*C+K0, can search original data, graph curve, parameters settings

    c. Can save 240 group curves, can test 240 data in each curve

    d. Double wavelength, Triple wavelength test functions

    3, Kinetics

    Used for time course scanning or reaction rate calculations A/t, can search all data.

    4, Multi-Wavelength

    Can test Transmittance and Abs. with 8 different wavelengths at most

    5, Scanning

    User can set the scan range from 190nm to 1100nm to test the max. Abs. peak value, can do derivation,

    arithmetical operationsto the graph.

    6, Biology

    6 methods: DNA/Protein, UV, Lowry, BCA,CBB and Biuret

  • Specification
  • Technical Parameters

    Model

    BS-UV1900

    BS-UV1900PC

    BS-V1900

     BS-V1900PC

    Optical System

    Single Beam, Grating 1200 lines/mm

    Wavelength Range

    190~1100nm

    320~1100nm

    Spectral Bandwidth

    2nm

    Wavelength Accuracy

    ± 0.5nm

    Wavelength Repeatability

    ≤ 0.3nm

    Photometric Accuracy

    ± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.5% T (0~100% T)

    Photometric Repeatability

    0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T)

    Stray Light

    ≤ 0.05% T @ 360nm; 220nm

    Stability

    ± 0.0008A / h @ 500nm

    Baseline Flatness

    ± 0.002A

    Noise

    0.0005Abs  @ 500nm

    Display

    480 *272  65 thousand true color TFT LCD

    Photometric Mode

    T, A, C, E

    Photometric Range

    0~200% T,-0.301~3.0A

    Detector

    Silicon Photodiode

    Light Source

    Deuterium Lamp, Tungsten Lamp

    Input

    Membrane Keypad

    Output

    USB2.0*2 Print and data output  USB1.0 Connect PC

    Standard Accessories

    10mm glass cuvette *4 units 10mm quartz cuvette *2 units

    10mm glass uvette *4 units

    Optional Accessories

    Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system

    Power Supply

    AC110V/220±10% ,60/50Hz

    Packing Size(mm)

    620*500*370

    620*500*370

    Gross Weight(kg)

    18

    16.5

     


  • Customer Reviews
  • Customer Reviews
    • Write a Review
      Average Rating:
      {{stardata.star}}
      based on {{comment.count}} reviews
    • {{comment.star5}}%
      {{comment.star4}}%
      {{comment.star3}}%
      {{comment.star2}}%
      {{comment.star1}}%
    No data
    BIOSTELLAR BS-V1900PC Scanning UV/VIS Spectrophotometer
    {{comments.user.name}}
    Verified Purchase
    {{comments.rating}}.0
    {{comments.date_added}}
    {{comments.topic}}
    {{comments.text}}
    Showing {{comments.replies.length}} comment

    {{reply_items.text}}By {{reply_items.author}}

  • Questions & Answers
  • Questions & Answers
    Ask a Question
    No data
    Your Browsing History
    {{item.displayed_price.rate_of_discount}} %
    OFF

    {{item.detail.name}}

    {{item.displayed_price.unit_prefix}} {{item.displayed_price.min}} {{item.displayed_price.unit_prefix}}  {{item.displayed_price.original_min}}

    Currency: USD
    USD - US Dollar
    EUR - Euro
    GBP - British Pound
    CAD - Canada Dollars
    AUD - Australia Dollars
    JPY - Japan Yen
    SEK - Sweden Kronor
    NOK - Norway Kroner
    IDR - Indonesia Rupiahs
    BRL - Brazil Reais
    RUB - Russia Rubles
    THB - Thailand Baht
    AED - Arab Emir. Dirham
    Need Help?
    Chat live with us
    Request Quote
    Track Order
    Want to check the status of your order? You can put in your order number and click track order to find the tracking information or login your account to check the detail information.
    order number
    • order number
    • tracking number