Laboratory Class II A2 Biosafety Cabinet for Microbiology and Cell Culture
- A collection tank is located at the bottom of the working area to collect spilled liquids for easy cleaning.
- It is equipped with a height limit alarm device, providing audible and visual alerts to ensure user safety.
- The outer casing is made of alloy steel plate with an anti-static treatment, making it easy to clean and rust-resistant.
|
Model |
BSC-1100ⅡA2-Z |
BSC-1300ⅡA2-Z |
BSC-1500ⅡA2-Z |
BSC-1800ⅡA2-Z |
|
|
Classification |
A2: 30% efflux, 70% internal circulation |
||||
|
Function |
Cleanliness |
Class 100/ISO 5 |
|||
|
Collection efficiency |
≥99.995% of 0.3um particle |
||||
|
Colony Count |
≤0.5/vessel (petri dish is φ90mm ) |
||||
|
Noise Level |
≤67db |
||||
|
Vibration Semi-Peak Value |
≤5um |
||||
|
Downdraft |
0.33土0.025m/s |
||||
|
Inflow flow |
0.55m土0.025m/s |
||||
|
Illumination Lntensity |
The measured value of each illuminance≥400 lx。 |
||||
|
Composition |
Inner Chamber |
SUS304 Stainless steel plate |
|||
|
Operation door |
Ultra-clear explosion-proof tempered glass |
||||
|
HEPA filter(mm) |
900*500*70*2pcs |
1296*530*70 &600*380*70 |
1330*505*70*2pcs |
1630*495*70*2pcs |
|
|
Fluorescent Lamp Power |
20W*2 |
30W*2 |
30W*2 |
30W*2 |
|
|
UV Light Power |
30W*1 |
30W*1 |
30W*1 |
30W*1 |
|
|
Rated Power |
1800W |
||||
|
Socket |
2pcs |
||||
|
Controller |
Maximum height of front window |
220 |
|||
|
Display |
Full color 7.0inch touch screen |
||||
|
Function |
Socket instrument controllable switch function, front window status display function, can set three position interlock function, cumulative work timing function |
||||
|
Specification |
Operating Area Size(W*L*H)(mm) |
925*600*670 |
1125*600*670 |
1325*600*670 |
1625*600*670 |
|
Exterior Size(W*L*H)(mm) |
1100*780*2185 |
1300*780*2185 |
1500*780*2185 |
1800*780*2200 |
|
-
Clinical Laboratories:For safe handling of biological and diagnostic samples.
-
Pharmaceutical & Biotechnology Companies:For sterile operations and contamination-sensitive processes.
-
Research Institutes & Universities:For microbiology and molecular biology research.
-
Hospitals & Medical Centers:For pathogen-related laboratory applications.
-
Food & Environmental Testing Laboratories:For microbial testing and contamination control.
- CE Certification
- EMC Compliance
- ISO 9001 Certified
- RoHS Certification
Q1: How does the biosafety cabinet handle accidental liquid spills?
Q2: Does the cabinet include any safety alarm functions?
Q3: Is the cabinet easy to clean and maintain?
Q4: What is the difference between Class I and Class II biosafety cabinets?
- Class I Biosafety Cabinets provide protection for the operator and the environment, but they do not protect the samples inside the cabinet from contamination. Air is drawn into the cabinet and filtered before being exhausted.
- Class II Biosafety Cabinets provide protection for the operator, the environment, and the product/sample. They use HEPA-filtered laminar airflow to maintain a clean working environment, making them ideal for microbiological research, cell culture, and pharmaceutical applications.
Class II cabinets are the most commonly used type in modern laboratories because they offer comprehensive protection during sensitive biological operations.
Q5: What protection does a Class II A2 cabinet provide?
- Personnel Protection
Protects the operator from exposure to hazardous aerosols and biological agents through inward airflow and HEPA filtration. - Product Protection
Maintains a sterile work area with vertical laminar HEPA-filtered airflow to prevent sample contamination. - Environmental Protection
Contaminated air passes through HEPA filters before recirculation or exhaust, preventing harmful particles from entering the laboratory environment.